• Working Hours: SUN - THU 8:30 AM - 05:00 PM
Suite 39, 5th Floor Al Mousa Commercial Tower, Dhahran

FL-Series Flood Light

//seco.net.sa/wp-content/uploads/2018/07/fl-series_cropped.jpg
LED FLOOD LIGHTS

FL-SERIES

OVERVIEW
The FL-Series LED bay/flood lights are using PHILIPS LUMILEDS® luminous source, providing excellent lumen output, long-las􀆟ng stability and splendid sight.
The FL-Series LED bay/flood lights have a high luminous efficiency and be􀆩er service life. Provide 7 years warranty on luminaire.

//seco.net.sa/wp-content/uploads/2018/07/7years_warranty-1.jpg
Download Data Sheet

ELECTRICAL & PHOTOMETRIC
3030 Version

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD40H4B
FL-FGD40H4B
95mA40W140 lm /w5600 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>100,000 (L70)
FL-GCD50H5B
FL-FGD50H5B
115mA50W130 lm /w6500 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>100,000 (L70)
FL-GCD60H6B
FL-FGD60H6B
145mA60W125 lm /w7500 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>80,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD80H4B
FL-FGD80H4B
100mA80W140 lm /w11200 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>100,000 (L70)
FL-GCD100H5B
FL-FGD100H5B
120mA100W130 lm /w13000 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>100,000 (L70)
FL-GCD120H6B
FL-FGD120H6B
145mA120W125 lm /w15000 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>80,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD120H4B
FL-FGD120H4B
100mA120W140 lm /w16800 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>100,000 (L70)
FL-GCD150H5B
FL-FGD150H5B
120mA150W130 lm /w19500 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>100,000 (L70)
FL-GCD180H6B
FL-FGD180H6B
145mA180W125 lm /w22500 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>80,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD160H4B
FL-FGD160H4B
100mA160W140 lm /w22400 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>100,000 (L70)
FL-GCD200H5B
FL-FGD200H5B
120mA200W130 lm /w26000 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>100,000 (L70)
FL-GCD240H6B
FL-FGD240H6B
145mA240W125 lm /w30000 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>80,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD200H4B
FL-FGD200H4B
100mA200W140 lm /w28000 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>100,000 (L70)
FL-GCD240H5B
FL-FGD240H5B
120mA240W130 lm /w31200 lm100-240V /277V AC 50 /60HzPhilips Lumileds 3030 2DMeanWell Inventronics60° 90° 110°3000*² 4000 5000 5700>100,000 (L70)

*¹ Model of Bay Light: FL-GCDXXHXB | Model of Flood Light: FL-FGDXXHXB.
*² Luminous Efficacy of 3000K is 5% lower than other CCTs.


5050 Version

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD40H4B
FL-FGD40H4B
48mA40W165 lm /w6600 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>85,000 (L70)
FL-GCD50H5B
FL-FGD50H5B
59mA50W160 lm /w8000 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>85,000 (L70)
FL-GCD60H6B
FL-FGD60H6B
75mA60W155 lm /w9300 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>80,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD80H4B
FL-FGD80H4B
50mA80W165 lm /w13200 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>85,000 (L70)
FL-GCD100H5B
FL-FGD100H5B
61mA100W160 lm /w16000 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>85,000 (L70)
FL-GCD120H6B
FL-FGD120H6B
75mA120W155 lm /w18600 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>80,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD120H4B
FL-FGD120H4B
50mA120W165 lm /w19800 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>85,000 (L70)
FL-GCD150H5B
FL-FGD150H5B
58mA150W160 lm /w24000 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>85,000 (L70)
FL-GCD180H6B
FL-FGD180H6B
75mA180W155 lm /w27900 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>80,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD160H4B
FL-FGD160H4B
50mA160W165 lm /w26400 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>85,000 (L70)
FL-GCD200H5B
FL-FGD200H5B
58mA200W160 lm /w32000 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>85,000 (L70)
FL-GCD240H6B
FL-FGD240H6B
75mA240W155 lm /w37200 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>80,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD200H4B
FL-FGD200H4B
50mA200W165 lm /w33000 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>85,000 (L70)
FL-GCD240H5B
FL-FGD240H5B
61mA240W160 lm /w38400 lm100-240V /277V AC 50 /60HzPhilips Lumileds 5050MeanWell Inventronics110°3000* 4000 5000 5700>85,000 (L70)

*¹ Model of Bay Light: FL-GCDXXHXB | Model of Flood Light: FL-FGDXXHXB.
*² Luminous Efficacy of 3000K is 5% lower than other CCTs.


3535 Version

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD40HB
FL-FGD40HB
860mA40w110 lm /w4400 lm100-240V /277V AC 50 /60HzPhilips Lumileds Luxeon TXMeanWell Inventronics60° 90° 110°3000*²
4000
5000
5700
>100,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD80HB
FL-FGD80HB
900mA80W110 lm /w8800 lm100-240V /277V AC 50 /60HzPhilips Lumileds Luxeon TXMeanWell Inventronics60° 90° 110°3000*²
4000
5000
5700
>100,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD120HB
FL-FGD120HB
900mA120W110 lm /w13200 lm100-240V /277V AC 50 /60HzPhilips Lumileds Luxeon TXMeanWell Inventronics60° 90° 110°3000*²
4000
5000
5700
>100,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD160HB
FL-FGD160HB
900mA160W110 lm /w17600 lm100-240V /277V AC 50 /60HzPhilips Lumileds Luxeon TXMeanWell Inventronics60° 90° 110°3000*²
4000
5000
5700
>100,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD200HB
FL-FGD200HB
900mA200W110 lm /w22000 lm100-240V /277V AC 50 /60HzPhilips Lumileds Luxeon TXMeanWell Inventronics60° 90° 110°3000*²
4000
5000
5700
>100,000 (L70)

ModelLED Working CurrentPowerLuminaire efficacy (+/- 5%)Lumen Output (+/- 5%)Input VoltageLED BrandDriver BrandLight DistributionsCCT (K)Lifetime (h)
FL-GCD240HB
FL-FGD240HB
900mA240W110 lm /w26400 lm100-240V /277V AC 50 /60HzPhilips Lumileds Luxeon TXMeanWell Inventronics60° 90° 110°3000*²
4000
5000
5700
>100,000 (L70)

*¹ Model of Bay Light: FL-GCDXXHXB | Model of Flood Light: FL-FGDXXHXB.
*² Luminous Efficacy of 3000K is 5% lower than other CCTs.


CERTIFICATION
Manufacturer
ISO9001, ISO14001
HB Series [ FL-GCD40HB, FL-GCD80HB, FL-GCD120HB, FL-GCD160HB, FL-GCD200HB, FL-GCD240HB􀀁]
HB Series [ FL-FGD40HB, FL-FGD80HB, FL-FGD120HB, FL-FGD160HB, FL-FGD200HB, FL-FGD240HB􀀁]
CE, ROHS, GS, CB, SAA, UL, cUL, DLC, LM79, LM80
H4B/H5B Series [ FL-GCD40H4B, FL-GCD80H4B, FL-GCD120H4B, FL-GCD160H4B, FL-GCD200H4B􀀁􀀁􀁝􀀁FL-GCD50H5B, FL-GCD100H5B, FL-GCD150H5B, FL-GCD200H5B, FL-GCD240H5B ]
H4B/H5B Series [ FL-FGD40H4B, FL-FGD80H4B, FL-FGD120H4B, FL-FGD160H4B, FL-FGD200H4B􀀁􀀁􀁝􀀁FL-FGD50H5B, FL-FGD100H5B, FL-FGD150H5B, FL-FGD200H5B, FL-FGD240H5B ]
CE, ROHS, LM80
H6B Series [ FL-GCD60H6B, FL-GCD120H6B, FL-GCD180H6B, FL-GCD240H6B􀀁􀀁􀁝􀀁FL-FGD60H6B, FL-FGD120H6B, FL-FGD180H6B, FL-FGD240H6B ]
CE, ROHS, LM80